Ryan Importico

Resume posted by Ryan81 in Building.

Desired position type: Full-Time
Location: Franklin Township New Jersey, United States

importico81@gmail.com
Tel:
732 648 9433
Mobile:

Summary

Ryan Importico

732 648 9433

370 Route 22 West
Apt 108
Green Brook NJ 08812

Education History
* HS Grad. WHRHS, Warren NJ 2001

* 1.5 years of RVCC North Branch NJ (did not Grad general study)

* 4 outta 5 years at Edward Gram Train Faultily Union Beach NJ (HVAC) (did not Grad however my last 4 semesters I had a very high grad avg. and the last semester I finished with all 100 accept in one class that grad was 105)

* Took a York 410a seminar (mostly a sells pitch on their new coil style at the time)

* EPA universal though Mainstream Engineering

* Took a Turbo Torch Seminar

Work History
* Industrial Cooling Corp
732 744 9200
5 to 6 years HVAC -install mostly service

* Vans Comfortemp
561 278 5232
1.5 years HVAC -residential installs

Experience
I have helped install and have even been witness to more then one Liebert Start up. Have done many Liebert inspections, on many Liebert models. Have changed many compressor’s from Liebert’s, as well as bearing, shafts, contactors, unloaders, UV bulbs, filters, humidifier canisters, ect. I know some of the Lieberts codes off my head. Have also worked a lot on Data Aire units as well as installed Data Aire units. (both water cooled and air cooled condenser’s.) Have worked a lot on the McQuay RPS model roof top, as well as the Trane intellapak roof top. Also on Carrier, and York roof top units. Have spent a lot of time on Mammoth and Governor Aire units, and other penthouse units. Changed screw compressor’s on Mammoth as well as more then one on a Dunham Bush chiller with air cooled condenser. Tube punching on many different chillers. Help put back together York centif. comp, for over haul, impeller repair, along with thrust bearing, and collar. Many Tower cleanings, and repairs. Evaporator, evaporative condenser, and chilled water coil replacement. Full understanding of the TXV and three way valve’s and how to trouble shoot them. The correct way to work with cat 5 wire. Understanding of low pressure chiller purge system, and on York the senor that controls it. Water pump seal replacement, as well as pump changes. I switched two building from using there old BMS system to control base board heat to controlling it from pneumatic relays off the perimeter VAV boxes. Boiler cleaning, and maintenance. Basic knowledge of the screw compressor, and the importance of the discharge super heat for oil return on Dunham Bush, as well as other screws, and know the number off my head. Full understanding of basic refrigeration and comfort cooling ie Discharge air static, temp, cfm, super heat sub cooling ect. Can braze, solder, thread and fit black pipe. Many installs, residential and roof tops. Can work with sheet metal. Motor changes, fan blade changes. Coil cleaning and repair. Leak testing. Can recover refrigerant both ways regular and push pull method. Understand fan speed controls, and pressure controls. Have work on teletrol, mostly installing sensors and converting VAV’s however I have worked using there system to control air flow and other goodies form the computer as well.

References

* Lenny Fraga 908 581 9349
* Danny Mezzina 732 693 7276
* Danny Greenhalgh 908 217 9936
* Jimmy Wurfel 908 217 9925
* Gerard Marshall 908 217 9906

Education

Ryan Importico
 
 
370 Route 22 West
Apt 108
Green Brook NJ 08812
 
Education History
  *  HS Grad. WHRHS, Warren NJ 2001
 
  *  1.5 years of RVCC North Branch NJ  (did not Grad general study)
 
  *  4 outta 5 years at Edward Gram Train Faultily Union Beach NJ (HVAC) (did not Grad however my last 4 semesters I had a very high grad avg. and the                                                     last semester I finished with all 100 accept in one class that grad was 105)
 
  *  Took a York 410a seminar (mostly a sells pitch on their new coil style at the time)
 
  *  EPA universal though Mainstream Engineering 
 
  *  Took a Turbo Torch Seminar
 
 
Work History
  *  Industrial Cooling Corp  
  5 to 6 years HVAC -install mostly service
 
  *  Vans Comfortemp
  1.5 years HVAC -residential installs
 
 
Experience 
  I have helped install and have even been witness to more then one Liebert Start up.  Have done many Liebert inspections, on many Liebert models. Have changed many compressor’s from Liebert’s, as well as bearing, shafts, contactors, unloaders, UV bulbs, filters, humidifier canisters,  ect.  I know some of the Lieberts codes off my head.  Have also worked a lot on Data Aire units as well as installed Data Aire units.  (both water cooled and air cooled condenser’s.)  Have worked a lot on the McQuay RPS model roof top, as well as the Trane intellapak roof top.  Also on Carrier, and York roof top units.  Have spent a lot of time on Mammoth and Governor Aire units, and other penthouse units.  Changed screw compressor’s on Mammoth as well as more then one on a Dunham Bush chiller with air cooled condenser.  Tube punching on many different chillers.  Help put back together York centif. comp, for over haul, impeller repair, along with thrust bearing, and collar.  Many Tower cleanings, and repairs.  Evaporator, evaporative condenser, and chilled water coil replacement.  Full understanding of the TXV and three way valve’s and how to trouble shoot them.   The correct way to work with cat 5 wire.  Understanding of low pressure chiller purge system, and on York the senor that controls it.  Water pump seal replacement, as well as pump changes.  I switched two building from using there old BMS system to control base board heat to controlling it from pneumatic relays off the perimeter VAV boxes.  Boiler cleaning, and maintenance.  Basic knowledge of the screw compressor, and the importance of the discharge super heat for oil return on Dunham Bush, as well as other screws, and know the number off my head.  Full understanding of basic refrigeration and comfort cooling ie  Discharge air static, temp, cfm, super heat sub cooling  ect.  Can braze, solder, thread and fit black pipe.  Many installs, residential and roof tops.  Can work with sheet metal.  Motor changes, fan blade changes.  Coil cleaning and repair.  Leak testing.  Can recover refrigerant both ways regular and push pull method.  Understand fan speed controls, and pressure controls.  Have work on teletrol, mostly installing sensors and converting VAV’s however I have worked using there system to control air flow and other goodies form the computer as well.
 
 
References 
 
  * Lenny Fraga 908 581 9349
  * Danny Mezzina 732 693 7276
  * Danny Greenhalgh 908 217 9936
  * Jimmy Wurfel 908 217 9925
  * Gerard Marshall 908 217 9906

Experience

Ryan Importico
 
 
370 Route 22 West
Apt 108
Green Brook NJ 08812
 
Education History
  *  HS Grad. WHRHS, Warren NJ 2001
 
  *  1.5 years of RVCC North Branch NJ  (did not Grad general study)
 
  *  4 outta 5 years at Edward Gram Train Faultily Union Beach NJ (HVAC) (did not Grad however my last 4 semesters I had a very high grad avg. and the                                                     last semester I finished with all 100 accept in one class that grad was 105)
 
  *  Took a York 410a seminar (mostly a sells pitch on their new coil style at the time)
 
  *  EPA universal though Mainstream Engineering 
 
  *  Took a Turbo Torch Seminar
 
 
Work History
  *  Industrial Cooling Corp  
  5 to 6 years HVAC -install mostly service
 
  *  Vans Comfortemp
  1.5 years HVAC -residential installs
 
 
Experience 
  I have helped install and have even been witness to more then one Liebert Start up.  Have done many Liebert inspections, on many Liebert models. Have changed many compressor’s from Liebert’s, as well as bearing, shafts, contactors, unloaders, UV bulbs, filters, humidifier canisters,  ect.  I know some of the Lieberts codes off my head.  Have also worked a lot on Data Aire units as well as installed Data Aire units.  (both water cooled and air cooled condenser’s.)  Have worked a lot on the McQuay RPS model roof top, as well as the Trane intellapak roof top.  Also on Carrier, and York roof top units.  Have spent a lot of time on Mammoth and Governor Aire units, and other penthouse units.  Changed screw compressor’s on Mammoth as well as more then one on a Dunham Bush chiller with air cooled condenser.  Tube punching on many different chillers.  Help put back together York centif. comp, for over haul, impeller repair, along with thrust bearing, and collar.  Many Tower cleanings, and repairs.  Evaporator, evaporative condenser, and chilled water coil replacement.  Full understanding of the TXV and three way valve’s and how to trouble shoot them.   The correct way to work with cat 5 wire.  Understanding of low pressure chiller purge system, and on York the senor that controls it.  Water pump seal replacement, as well as pump changes.  I switched two building from using there old BMS system to control base board heat to controlling it from pneumatic relays off the perimeter VAV boxes.  Boiler cleaning, and maintenance.  Basic knowledge of the screw compressor, and the importance of the discharge super heat for oil return on Dunham Bush, as well as other screws, and know the number off my head.  Full understanding of basic refrigeration and comfort cooling ie  Discharge air static, temp, cfm, super heat sub cooling  ect.  Can braze, solder, thread and fit black pipe.  Many installs, residential and roof tops.  Can work with sheet metal.  Motor changes, fan blade changes.  Coil cleaning and repair.  Leak testing.  Can recover refrigerant both ways regular and push pull method.  Understand fan speed controls, and pressure controls.  Have work on teletrol, mostly installing sensors and converting VAV’s however I have worked using there system to control air flow and other goodies form the computer as well.
 
 
References 
 
  * Lenny Fraga 908 581 9349
  * Danny Mezzina 732 693 7276
  * Danny Greenhalgh 908 217 9936
  * Jimmy Wurfel 908 217 9925
  * Gerard Marshall 908 217 9906

Skills

  • Ryan Importico
  • 732 648 9433
  • 370 Route 22 West
  • Apt 108
  • Green Brook NJ 08812
  • Education History
  • * HS Grad. WHRHS, Warren NJ 2001
  • * 1.5 years of RVCC North Branch NJ (did not Grad general study)
  • * 4 outta 5 years at Edward Gram Train Faultily Union Beach NJ (HVAC) (did not Grad however my last 4 semesters I had a very high grad avg. and the last semester I finished with all 100 accept in one class that grad was 105)
  • * Took a York 410a seminar (mostly a sells pitch on their new coil style at the time)
  • * EPA universal though Mainstream Engineering
  • * Took a Turbo Torch Seminar
  • Work History
  • * Industrial Cooling Corp
  • 732 744 9200
  • 5 to 6 years HVAC -install mostly service
  • * Vans Comfortemp
  • 561 278 5232
  • 1.5 years HVAC -residential installs
  • Experience
  • I have helped install and have even been witness to more then one Liebert Start up. Have done many Liebert inspections, on many Liebert models. Have changed many compressor’s from Liebert’s, as well as bearing, shafts, contactors, unloaders, UV bulbs, filters, humidifier canisters, ect. I know some of the Lieberts codes off my head. Have also worked a lot on Data Aire units as well as installed Data Aire units. (both water cooled and air cooled condenser’s.) Have worked a lot on the McQuay RPS model roof top, as well as the Trane intellapak roof top. Also on Carrier, and York roof top units. Have spent a lot of time on Mammoth and Governor Aire units, and other penthouse units. Changed screw compressor’s on Mammoth as well as more then one on a Dunham Bush chiller with air cooled condenser. Tube punching on many different chillers. Help put back together York centif. comp, for over haul, impeller repair, along with thrust bearing, and collar. Many Tower cleanings, and repairs. Evaporator, evaporative condenser, and chilled water coil replacement. Full understanding of the TXV and three way valve’s and how to trouble shoot them. The correct way to work with cat 5 wire. Understanding of low pressure chiller purge system, and on York the senor that controls it. Water pump seal replacement, as well as pump changes. I switched two building from using there old BMS system to control base board heat to controlling it from pneumatic relays off the perimeter VAV boxes. Boiler cleaning, and maintenance. Basic knowledge of the screw compressor, and the importance of the discharge super heat for oil return on Dunham Bush, as well as other screws, and know the number off my head. Full understanding of basic refrigeration and comfort cooling ie Discharge air static, temp, cfm, super heat sub cooling ect. Can braze, solder, thread and fit black pipe. Many installs, residential and roof tops. Can work with sheet metal. Motor changes, fan blade changes. Coil cleaning and repair. Leak testing. Can recover refrigerant both ways regular and push pull method. Understand fan speed controls, and pressure controls. Have work on teletrol, mostly installing sensors and converting VAV’s however I have worked using there system to control air flow and other goodies form the computer as well.
  • References
  • * Lenny Fraga 908 581 9349
  • * Danny Mezzina 732 693 7276
  • * Danny Greenhalgh 908 217 9936
  • * Jimmy Wurfel 908 217 9925
  • * Gerard Marshall 908 217 9906

916 total views, 1 today